{"id":22466,"date":"2024-07-08T11:20:46","date_gmt":"2024-07-08T09:20:46","guid":{"rendered":"http:\/\/127.0.0.1:8080\/en\/organisation\/departments\/department-thermodynamics-and-energy-engineering\/laboratories\/laboratory-of-refrigeration\/"},"modified":"2025-10-23T14:48:12","modified_gmt":"2025-10-23T12:48:12","slug":"laboratory-of-refrigeration","status":"publish","type":"page","link":"https:\/\/riteh.uniri.hr\/en\/organisation\/departments\/department-thermodynamics-and-energy-engineering\/laboratory-of-refrigeration\/","title":{"rendered":"Laboratory of Refrigeration"},"content":{"rendered":"\n<p>Head: <a href=\"\/en\/osoba\/igor-bonefacic\/\">Assoc. Prof. Igor Bonefa\u010di\u0107<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Laboratory facilities<\/h2>\n\n\n\n<p>Room 0-88 located in the basement of the laboratory building, total floor area 278 m2 shared with Laboratory of Heating, Ventilation and Air-Conditioning and Laboratory of Thermal measurements. Laboratory of Refrigeration uses approximately 90 m2.<\/p>\n\n\n\n<p><br>Room 2-122 at the first floor of laboratory building, total floor area 24 m2 shared with Laboratory of Heating, Ventilation and Air-Conditioning.<\/p>\n\n\n\n<p><br>Room 2-121 at the first floor of laboratory building, total floor area 147 m2 shared with Laboratory of Heating, Ventilation and Air-Conditioning and Laboratory of Thermal measurements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Laboratory activities<\/h2>\n\n\n\n<p>Teaching, scientific research and professional work in refrigeration, building energetics and thermal energy systems.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Scientific activities<\/h3>\n\n\n\n<p>Experimental research as a part of activities on scientific papers\u2019 preparation, projects and dissertations in the field of refrigeration and heat pump technology and application.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Scientific projects<\/h4>\n\n\n\n<h4 class=\"wp-block-heading\"><em>Finished<\/em><\/h4>\n\n\n\n<p>Applied research of refrigeration systems with new refrigerants; Project No. 069-0692972-2203 Croatian ministry of science, education and sport RH, 2007. &#8211; 2013., principal researcher prof. Branimir Pavkovi\u0107, D. Sc.<\/p>\n\n\n\n<p><br>Numerical modelling and optimization of refrigeration equipment and systems; Project No. 0069-017 Croatian ministry of science and technology 2002. &#8211; 2006., principal researcher prof. Branimir Pavkovi\u0107, D. Sc.<\/p>\n\n\n\n<p><br>Applied research of trigeneration systems with heat pumps operating with natural refrigerants, Research project University of Rijeka 2014. \u2013 2018., principal researcher prof. Branimir Pavkovi\u0107, D. Sc.<br><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><em>Active<\/em><\/h4>\n\n\n\n<p>Optimization of heat pumps and refrigeration systems with low global warming potential refrigerants using numerical simulation, Research project University of Rijeka 2014. \u2013 2018., principal researcher prof. Branimir Pavkovi\u0107, D. Sc.<\/p>\n\n\n\n<p><a href=\"https:\/\/spapp.uniri.hr\/projekti\/ProjectNO1801\/Details\/1141\">https:\/\/spapp.uniri.hr\/projekti\/ProjectNO1801\/Details\/1141<\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>Enhancement of the heat exchanger energy efficiency (HEXENER) \u2013 Croatian Science Foundation, principal researcher prof. Anica Trp D. Sc.<\/p>\n\n\n\n<p><a href=\"http:\/\/www.riteh.uniri.hr\/en\/znanost-old\/existing-projects\/hexener\/\">http:\/\/www.riteh.uniri.hr\/en\/znanost-old\/existing-projects\/hexener\/<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Teaching activities<\/h3>\n\n\n\n<p>Laboratory practice and presentation of the operation of refrigeration systems within the courses Refrigeration, Compressors, Laboratory practice, Process Plant Equipment and Marine HVACR Systems at the graduate university study of mechanical engineering.<\/p>\n\n\n\n<p><br>Measurements within the preparation of doctoral dissertations and support in the implementation of postgraduate doctoral studies in the courses Selected Chapters on Refrigeration, Environmental Refrigeration and Numerical Modeling in Refrigeration.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Professional activities<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Preliminary energy studies and reports on energy audits within the preparation of energy certificates for buildings in the Republic of Croatia.<\/li>\n\n\n\n<li>Energy studies and feasibility studies of HVAC\uf026R systems. <\/li>\n\n\n\n<li>Professional projects of HVAC\uf026R systems. <\/li>\n\n\n\n<li>Thermographic inspections of buildings and industrial facilities.<\/li>\n\n\n\n<li>Participation in the development of computer programs for determining the energy performance of buildings and their systems.<\/li>\n\n\n\n<li>Training of refrigeration system service technicians for operation and maintenance of refrigeration and air conditioning devices according to the project MP \/ CRO \/ 99\/099 (2001-2013).<\/li>\n\n\n\n<li>Education and training of authorized service technicians to perform the activities of collection, leakage inspection, installation and maintenance or servicing of refrigeration and air conditioning units and heat pumps in accordance with the Regulation on certain fluorinated greenhouse gases (EC 517\/2014) carried out in cooperation with the Croatian Association for refrigeration, air conditioning and heat pumps (HURKT)<\/li>\n\n\n\n<li>Education and training of those authorized for energy audits and certification of buildings with simple and complex systems.<\/li>\n\n\n\n<li>Education and training of authorized persons for energy audits and certification of large systems.<\/li>\n\n\n\n<li>Education and training of authorized service technicians to perform the activities of collection, leakage inspection, installation and maintenance or servicing of refrigeration and air conditioning devices and heat pumps that use CO2 or flammable refrigerants as a working substance<br> <\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public\/2a\/24\/2a24b050-de94-4b33-bd76-9a8c90116b39\/real_alternatives_4_life.jpg\" alt=\"real_alternatives_4_life.jpg\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><\/h3>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/ba\/65\/ba6531ee-3a17-4c6e-b5bf-2e1ae4e00b99\/slika1.jpg__300x479_q92_crop_subsampling-2_upscale.jpg\" alt=\"slika1.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Laboratory equipment and systems<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Solar cooling system<\/h4>\n\n\n\n<p>An experimental system of solar absorption cooling was installed in the laboratory of refrigeration financed by European project MED EMILIE and Faculty\u2019s own funds.<\/p>\n\n\n\n<p>The system enables cooling of the laboratory facility and it is used for educational and research purposes.<\/p>\n\n\n\n<p>The cooling device works with a mixture of ammonia and water, its cooling capacity is 18.6 kW at at cooled water temperature of 6\/12\u00b0C, heating water temperature from solar collectors 85\/78\u00b0C and water temperature for cooling condenser and absorber 30\/24\u00b0C. The required heat generated by solar collectors under these conditions is 30 kW, and the waste heat to be dissipated by the cooling tower is 49 kW.<\/p>\n\n\n\n<p>The heat generated by absorber and condenser of the refrigeration unit is dissipated via an open cooling tower, a cooling effect of 131 kW at an outdoor air temperature of 31\u00b0C and a wet bulb temperature of 28\u00b0C.<\/p>\n\n\n\n<p>The production of driving heat is through vacuum solar collectors with a total absorber area of \u200b\u200b65 m<sup>2<\/sup>. The collectors are connected to each other in 4 groups of 5 collectors, located on the roof of the laboratory building, absorbers oriented to the south and inclined to the horizontal plane at an angle of 35\u00b0, which is carried out by rotating vacuum tubes around their axes lying in the horizontal plane.<\/p>\n\n\n\n<p>In order to ensure the use of heat from solar collectors during the winter, to avoid possible increases in temperature and steam generation in the collectors and to ensure maximum utilization of solar energy, this project also envisages the use of solar energy for heating purposes. This is done by reheating the water from the laboratory building\u2019s heating system via solar collectors.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/fe\/f0\/fef01aa2-b882-4e71-820b-3328307e8669\/apsorpcijski_1.png__800x632_q92_crop_subsampling-2_upscale.jpg\" alt=\"apsorpcijski_1.png\"\/><\/figure>\n\n\n\n<p>Simplified scheme of solar cooling system<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/9a\/ea\/9aea20d1-fbe4-468a-a50a-2b4c2d504718\/kolektorsko_polje1.jpg__800x437_q92_crop_subsampling-2_upscale.jpg\" alt=\"kolektorsko_polje1.jpg\"\/><\/figure>\n\n\n\n<p>Collector field, cooling tower, dry cooler<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/5f\/7c\/5f7cbda9-93fe-4bad-8ffe-3392c62288d2\/apsorbcijski_pumpa.jpg__1153x981_q92_crop_subsampling-2_upscale.jpg\" alt=\"apsorbcijski_pumpa.jpg\"\/><\/figure>\n\n\n\n<p>Absorption cooling device (left) and circulation pump at the outlet to the collectors (right)<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/95\/51\/955138e5-1f3d-401f-b41f-2a02f63c275a\/topli_i_hladni_spremnik.jpg__1377x930_q92_crop_subsampling-2_upscale.jpg\" alt=\"topli_i_hladni_spremnik.jpg\"\/><\/figure>\n\n\n\n<p>Hot (left) and cold (right) heat storage<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/a1\/1f\/a11f93a1-bf3e-466d-903c-9c1d04ecef69\/strojarnica.jpg__1226x817_q92_crop_subsampling-2_upscale.jpg\" alt=\"strojarnica.jpg\"\/><\/figure>\n\n\n\n<p>Machine room<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/cc\/57\/cc57f903-d47b-4263-b916-5441928ba992\/ormaric_reg.jpg__2043x951_q92_crop_subsampling-2_upscale.jpg\" alt=\"ormaric_reg.jpg\"\/><\/figure>\n\n\n\n<p>Automatic control cabinet and collector field detail<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/11\/94\/1194f9b6-24b7-4267-9787-f6d251426b89\/mjerene_vrijednost_temp.png__2080x1045_q92_crop_subsampling-2_upscale.png\" alt=\"mjerene_vrijednost_temp.png\"\/><\/figure>\n\n\n\n<p>Measured values of temperatures in the hot and cold tank and at the outlet of the solar collector field, September 22, 2015<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/8a\/80\/8a8022eb-4250-4f1c-abb0-5f42cd32eecd\/mjerene_vrijednosti_intenziteta.png__2059x1045_q92_crop_subsampling-2_upscale.png\" alt=\"mjerene_vrijednosti_intenziteta.png\"\/><\/figure>\n\n\n\n<p>Measured values of solar radiation intensity, September 22, 2015<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/24\/1a\/241a64c7-da2f-4893-81e7-92fda86f6286\/toplinske_bilance.png__2080x1048_q92_crop_subsampling-2_upscale.png\" alt=\"toplinske_bilance.png\"\/><\/figure>\n\n\n\n<p>Heat balances, September 22, 2015<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Cold storage with transcritical refrigeration unit working with CO<sub>2<\/sub><\/h4>\n\n\n\n<p>Refrigeration unit with CO<sub>2<\/sub> refrigerant that works according to the transcritical cycle is one of the newer technical solutions for refrigeration devices in commercial applications. It was procured with the funds of the Faculty, while the corresponding cold store was donated by the manufacturer, the company MB Frigo d.o.o. from Zagreb. The device is equipped with an associated control and measuring system that allows monitoring of all operating parameters. As part of the classes in the course Refrigeration and Ship HVAC&amp;R systems, exercises are held in which students are introduced to the operational principles. The device also provides performing the practical training for refrigeration service technicians. A dissertation is being prepared in which measurements intended for the evaluation of a computer model for simulating the operating parameters of the system in non-stationary operating conditions will be performed on this device.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/1e\/ed\/1eede8fe-f1c3-4aa1-bc7a-1efa5692129e\/hladionica1.jpg__1875x1152_q92_crop_subsampling-2_upscale.jpg\" alt=\"hladionica1.jpg\"\/><\/figure>\n\n\n\n<p>Cold storage and evaporator<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/ee\/6c\/ee6c26b4-3371-4606-aa27-bb84d5977429\/hladionica2.jpg__1696x1153_q92_crop_subsampling-2_upscale.jpg\" alt=\"hladionica2.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/c6\/ed\/c6ed7520-d156-4e2b-a613-8d548bbbe206\/hladionica3.jpg__1980x1011_q92_crop_subsampling-2_upscale.jpg\" alt=\"hladionica3.jpg\"\/><\/figure>\n\n\n\n<p>Condensing unit ARCTICO2 30 MB Frigo: compressor Toshiba DY30N1F-10FU (25 -100 rps), refrigerant R744, cooling capacity 0,7 \u2013 2,8 kW (evaporation temperature -7\u00b0C, gas coole outlet temperature 35\u00b0C, superheating 10K). Gas cooler design pressure 120 bar. Evaporator design pressure 80 bar.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/ad\/64\/ad6440e7-ec92-49a5-9895-93a9c3ef63e7\/hladionica4.jpg__1976x819_q92_crop_subsampling-2_upscale.jpg\" alt=\"hladionica4.jpg\"\/><\/figure>\n\n\n\n<p>Monitoring and control (Carel HECU i BOSS)<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/68\/c6\/68c6a727-f52e-4ad3-adb8-aecaf1f7b987\/hladionica5.png__624x326_q92_crop_subsampling-2_upscale.png\" alt=\"hladionica5.png\"\/><\/figure>\n\n\n\n<p>Pressure measurement log<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/a4\/c4\/a4c42d60-f7f9-41fa-862d-6198eaa08d57\/hladionica6.png__624x334_q92_crop_subsampling-2_upscale.png\" alt=\"hladionica6.png\"\/><\/figure>\n\n\n\n<p>Pressure measurement log<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/f2\/73\/f273ce6c-1885-4e11-84b1-18041d5dbe92\/hladionica7.jpg__1430x728_q92_crop_subsampling-2_upscale.jpg\" alt=\"hladionica7.jpg\"\/><\/figure>\n\n\n\n<p>Front panel of the control unit<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/85\/c6\/85c67591-1091-421f-b930-a0d0401266bb\/hladionica8.png__3900x1889_q92_crop_subsampling-2_upscale.png\" alt=\"hladionica8.png\"\/><\/figure>\n\n\n\n<p>Operating points of the device (transcritical process)<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/82\/d9\/82d93f72-1138-4dd0-babb-ecb5f07a8780\/hladionica9.jpg__1589x620_q92_crop_subsampling-2_upscale.jpg\" alt=\"hladionica9.jpg\"\/><\/figure>\n\n\n\n<p>In cooperation of the Faculty and the Croatian Association for Refrigeration Air Conditioning and Heat Pumps, the laboratory conducts practical training and development of refrigeration service technicians to work with devices that contain CO<sub>2<\/sub> as a working substance.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Draft beverage cooler with the latent heat storage<\/h4>\n\n\n\n<p>The device is donated by the company Oprema d.d. from Ludbreg. It is intended for cooling beverages when they are dispensed. The device is equipped for the implementation of measurements of operating parameters within the dissertation aimed at developing an integrated computer model of a refrigeration unit with latent accumulation that should serve to optimize the design of such devices in order to achieve increased energy efficiency.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/fb\/4e\/fb4eec9a-4ecf-4230-85a8-0c029b1aa23d\/rashladni_1.jpg__1749x1152_q92_crop_subsampling-2_upscale.jpg\" alt=\"rashladni_1.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/3a\/b1\/3ab161fe-0aa0-4adb-9783-a1c0c1e4a13d\/rashladni_shema.png__654x356_q92_crop_subsampling-2_upscale.png\" alt=\"rashladni_shema.png\"\/><\/figure>\n\n\n\n<p>Simplified scheme of draft beverage cooling system<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/02\/9e\/029e3838-1b0c-4e30-ac0d-6e85de0f8e9a\/rashladni_simulacije.jpg__1581x2359_q92_crop_subsampling-2_upscale.jpg\" alt=\"rashladni_simulacije.jpg\"\/><\/figure>\n\n\n\n<p>Computer simulations and experimental verification of ice formation on evaporator tubes<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Vapor compression single stage refrigeration unit<\/h4>\n\n\n\n<p>The device is intended to acquaint students with the principle of operation, the method of regulation and the interdependence of the operating parameters of refrigeration devices on the characteristics of individual components. It is also used for training of refrigeration service technicians engaged in working with refrigeration devices and their basic components, as well as for better acquaintance with refrigerants. It is equipped with inverter control of compressor supply and measurement of the flow of the refrigerant.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/90\/74\/90742b08-5086-4e5f-9f0c-ba00b7e287df\/parno_kompresijski.jpg__600x379_q92_crop_subsampling-2_upscale.jpg\" alt=\"parno_kompresijski.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/60\/e3\/60e349fa-46fe-4cb5-8945-3989f6c99a2f\/parno_kompresijski_2.jpg__600x263_q92_crop_subsampling-2_upscale.jpg\" alt=\"parno_kompresijski_2.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/be\/e5\/bee516a7-07ae-4221-824f-31f64564af37\/parnokompresijski3.jpg__600x283_q92_crop_subsampling-2_upscale.jpg\" alt=\"parnokompresijski3.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/f6\/8f\/f68f9fb5-4e6d-4a4a-a0a3-52e0e6fc3f26\/parno_kompresijski4.jpg__610x370_q92_crop_subsampling-2_upscale.jpg\" alt=\"parno_kompresijski4.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/aa\/c1\/aac138c2-c836-4793-b186-049416481652\/parno_kompresijski5.jpg__600x287_q92_crop_subsampling-2_upscale.jpg\" alt=\"parno_kompresijski5.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/e0\/d9\/e0d93f55-86e8-4f98-b826-decd064fdfef\/parno_kompresijski6.jpg__600x446_q92_crop_subsampling-2_upscale.jpg\" alt=\"parno_kompresijski6.jpg\"\/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Heat pumps<\/h4>\n\n\n\n<p>All heat pumps in the refrigeration laboratory are connected in a single system that is integrated with the heating and cooling systems in the laboratory building. Heat pumps are equipped with inverter compressor control, devices for measuring refrigerant temperatures, pressures and mass flow, water temperature and mass flow, and compressor power. Measuring devices can be connected to acquisition systems that are an integral part of laboratory equipment and are intended for data collection and implementation of complex measurements. From the heat pumps shown in the pictures, the refrigerant R22 with which they were originally filled was removed and disposed and heat pumps were retrofitted and converted for use of new environmentally friendly refrigerants (HFC mixtures with low impact on global warming and propane).<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/8f\/cf\/8fcf66fc-72cf-440f-a689-181d021aac16\/diz1.jpg__600x757_q92_crop_subsampling-2_upscale.jpg\" alt=\"diz1.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/14\/a2\/14a23c92-ae1c-429c-8488-5f858a858735\/diz2.jpg__600x766_q92_crop_subsampling-2_upscale.jpg\" alt=\"diz2.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/14\/a2\/14a23c92-ae1c-429c-8488-5f858a858735\/diz2.jpg__600x766_q92_crop_subsampling-2_upscale.jpg\" alt=\"diz2.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/d3\/49\/d3495f4b-01ae-4239-be12-72ee54037db3\/diz3.jpg__600x515_q92_crop_subsampling-2_upscale.jpg\" alt=\"diz3.jpg\"\/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Tools and equipment for working on refrigeration systems<\/h4>\n\n\n\n<p>The laboratory has all the necessary equipment for refrigerant recovery, recycling and leakage detection, measurement of operating parameters as well as service equipment.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/ea\/dd\/eadd6f69-c4be-45c7-a708-3d3263652b0a\/alati_oprema_1.jpg__600x602_q92_crop_subsampling-2_upscale.jpg\" alt=\"alati_oprema_1.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/ef\/b5\/efb5e040-f740-4755-bd6f-cbd46ce2187f\/alati_oprema_2.jpg__600x793_q92_crop_subsampling-2_upscale.jpg\" alt=\"alati_oprema_2.jpg\"\/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Small instruments<\/h4>\n\n\n\n<p>The laboratory uses several smaller instruments intended for measuring electrical quantities and operating parameters of devices and machines.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/dd\/3c\/dd3c8732-b5c0-450d-a297-2143910c6204\/mali_mjerni.jpg__944x640_q92_crop_subsampling-2_upscale.jpg\" alt=\"mali_mjerni.jpg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p>The laboratory is equipped with the necessary instruments to perform measurements on systems with water and air as heat transfer fluids.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/34\/9e\/349e168a-5620-48f4-b1d4-072e88e7547c\/sustavi.jpg__502x350_q92_crop_subsampling-2_upscale.jpg\" alt=\"sustavi.jpg\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/ed\/7a\/ed7a5b28-ef46-4d24-b7df-6886609d3f1c\/sustavi2.jpg__237x350_q92_crop_subsampling-2_upscale.jpg\" alt=\"sustavi2.jpg\"\/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Thermal imaging camera<\/h4>\n\n\n\n<p>It is used in the implementation of energy audits of buildings and in the analysis of the thermal state of technical systems in the laboratory.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/04\/81\/0481b229-5aea-44d8-9563-bd75429f0dff\/image96.jpeg__466x350_q92_crop_subsampling-2_upscale.jpg\" alt=\"image96.jpeg\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/2e\/80\/2e80a096-da5d-4fca-b752-aae6d9b73024\/image97.png__472x350_q92_crop_subsampling-2_upscale.jpg\" alt=\"image97.png\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Heat flow measuring device<\/h4>\n\n\n\n<p>It is used to measure the coefficients of heat transfer through the elements of building structures in the implementation of energy audits of buildings and in laboratory exercises for students of thermal engineering.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/e9\/09\/e9092d94-d738-41ac-b729-332249310aed\/image880.jpeg__466x350_q92_crop_subsampling-2_upscale.jpg\" alt=\"image880.jpeg\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"\/media\/filer_public_thumbnails\/filer_public\/15\/56\/1556c7ce-2fd7-422c-a93a-ed2d248479b8\/image99.jpeg__219x350_q92_crop_subsampling-2_upscale.jpg\" alt=\"image99.jpeg\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cooperation with other laboratories of the Faculty<\/h3>\n\n\n\n<p>Laboratory for heating, ventilation and air-conditioning<\/p>\n\n\n\n<p>Laboratory of thermal measurements<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Financing<\/h3>\n\n\n\n<p>Faculty own resources<\/p>\n\n\n\n<p>Funds of professional projects<\/p>\n\n\n\n<p>Donations from companies and associations<\/p>\n\n\n\n<p>Funds from scientific and EU projects, incentive projects of the University of Rijeka, etc.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Head: Assoc. Prof. Igor Bonefa\u010di\u0107 Laboratory facilities Room 0-88 located in the basement of the laboratory building, total floor area 278 m2 shared with Laboratory of Heating, Ventilation and Air-Conditioning and Laboratory of Thermal measurements. Laboratory of Refrigeration uses approximately 90 m2. Room 2-122 at the first floor of laboratory building, total floor area 24 [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":22462,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-22466","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/pages\/22466","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/comments?post=22466"}],"version-history":[{"count":5,"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/pages\/22466\/revisions"}],"predecessor-version":[{"id":45101,"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/pages\/22466\/revisions\/45101"}],"up":[{"embeddable":true,"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/pages\/22462"}],"wp:attachment":[{"href":"https:\/\/riteh.uniri.hr\/en\/wp-json\/wp\/v2\/media?parent=22466"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}